The VGA-200 is use in Human Measurement Systems that employ contextual stimuli. The VGA splitter controls the subject's monitor so that only the stimulus is presented to the subject.
PC MOUSE SPLITTER
Contact our Behavioral Research Specialists for more information
The Mouse Splitter is used in Script Driven Imagery systems. Controls when the subject's mouse is active for responding.
STROOP RESPONSE CONSOLE
Contact our Behavioral Research Specialists for more information
A console with switches used in Modified Stroop Procedure systems.
P3 AUXILIARY RELAY - SINGLE POLE/SINGLE THROW
Contact our Behavioral Research Specialists for more information
REUSABLE ELECTRODE - 8 MM (SILVER CHLORIDE)
Contact our Behavioral Research Specialists for more information
Sintered-pellet silver chloride electrodes for general skin surface signal pickup applications. The V91-01 and V91-04 are 8 mm electrodes. The V91-02 and V91-03 are 4 mm electrodes. The V91-01 and V91-02 have a snap connection and require the V91-11 and V91-12 pinch electrode leads. The V91-03 and V91-04 are manufactured with the electrode lead attached to the electrode.
REUSABLE ELECTRODE - 4 MM (SILVER CHLORIDE)
Contact our Behavioral Research Specialists for more information
Sintered-pellet silver chloride electrodes for general skin surface signal pickup applications. The V91-01 and V91-04 are 8 mm electrodes. The V91-02 and V91-03 are 4 mm electrodes. The V91-01 and V91-02 have a snap connection and require the V91-11 and V91-12 pinch electrode leads. The V91-03 and V91-04 are manufactured with the electrode lead attached to the electrode.
REUSABLE - 4MM (SILVER CHLORIDE) WITH LEAD WIRE
Contact our Behavioral Research Specialists for more information
Sintered-pellet silver chloride electrodes for general skin surface signal pickup applications. The V91-01 and V91-04 are 8 mm electrodes. The V91-02 and V91-03 are 4 mm electrodes. The V91-01 and V91-02 have a snap connection and require the V91-11 and V91-12 pinch electrode leads. The V91-03 and V91-04 are manufactured with the electrode lead attached to the electrode.
REUSABLE - 8MM (SILVER CHLORIDE) WITH LEAD WIRE
Contact our Behavioral Research Specialists for more information
Sintered-pellet silver chloride electrodes for general skin surface signal pickup applications. The V91-01 and V91-04 are 8 mm electrodes. The V91-02 and V91-03 are 4 mm electrodes. The V91-01 and V91-02 have a snap connection and require the V91-11 and V91-12 pinch electrode leads. The V91-03 and V91-04 are manufactured with the electrode lead attached to the electrode.
3-LEAD ELECTRODE GROUND SPLITTER 1.5MM DIN
Contact our Behavioral Research Specialists for more information
The V91-05 3-Lead Electrode Ground Splitter permits the use of one ground electrode to be used up to three different isolated bioamplifiers. When using multiple isolated bioamplifers on a single subject, it is necessary that each bioamplifier have a ground electrode. The V91-05 allows one electrode to be connected to 3 isolated bioamplifiers eliminating the need for two ground electrodes. The V91-05 should not be used with non-isolated bioamplifiers as only one ground electrode should be used when using multiple non-isolated bioamplifiers.
PINCH TYPE ELECTRODE
Contact our Behavioral Research Specialists for more information
The V91-11 Pinch Electrode Lead and the V91-12 Mini-Pinch Electrode Lead are used with the V91-01 and V91-02 electrodes for connecting the electrodes to the Electrode cable. These leads feature the DIN safety termination. Either electrode lead may be used with either electrode. The pinch-type heads provide a positive, firm grip on the attachment dome of the V91-01 or -02 electrode as well as other snap-compatible electrodes, including the disposable types. This leads' firm grip eliminates one of the most significant sources of artifact, specifically that caused by slippage of the connection.