SHOCK LEVEL TESTER
SHOCK LEVEL TESTER
Contact our Behavioral Research Specialists for more information

The A13-16 Shock Level Tester allows for easy verification of the shock output of the aH13-15 or H13-17A shock generator. This unit requires a voltmeter and/or oscilloscope (not included). The input jack connects to alligator clips (included) that can easily be attached to either subject electrodes or the grids of the shock floor.

This unit provides two output options for verification. The first is a rectified DC output that can be used with any standard voltmeter to measure the peak current applied. In order to meet the requirements of more rigorous verification, the second output provided is for connection to an oscilloscope. This allows for visualization of the shock pulses in addition to peak measurements.
PRECISION ANIMAL SHOCKER -MANUAL ONLY
PRECISION ANIMAL SHOCKER -MANUAL ONLY
Contact our Behavioral Research Specialists for more information

This research grade, precision feedback, current-regulated shocker is totally isolated (floating output) for operator and subject safety, as well as isolation from other sources of electrical stimulation such as physiological stimulators that may be in use concurrently. Isolation is achieved by using an isolated transformer along with optical isolation of the inputs from the control equipment. The unit can function as a two-pole (bipolar) current reversal "square wave" output, or as a scanner distributing the polarity reversal across an 8-pole output for grid floor applications. Mode selection is made by a switch on the back. The grid outputs are direct "Form C" semiconductor switches. The "off" grids have zero resistance so the subject receives the same current regardless of the number of grids contacted.

This devices is available in two versions:
  • H13-15 -> PRECISION ANIMAL SHOCKER 110V
  • H13-15-220 -> PRECISION ANIMAL SHOCKER 220V
PRECISION ANIMAL SHOCKER - MANUAL AND PROGRAMMABLE
PRECISION ANIMAL SHOCKER - MANUAL AND PROGRAMMABLE
Contact our Behavioral Research Specialists for more information

The H13-17 shocker is totally isolated (floating output) for operator and subject safety, as well as isolation from other sources of electrical stimulation such as physiological stimulators that may be in use concurrently. The unit can function as a two-pole (bipolar) shocker or as a scanner distributing the square wave, polarity reversal across an 8-pole output for grid floor applications. Shock amplitudes from as small as one microamp (0.001 milliamp) to five milliamps can be delivered in increments of one microamp with the H13-17. The amplitude can be set manually or can be programmed by a 0 to 2.5 Volt DC signal allowing the amplitude of the shock stimulus to be changed during an experimental session. The onset and duration of the shock stimulus can be controlled by an external trigger source (5 to 30 volts DC) or when precision timing is not required, by manually pressing a button on the front panel of the shocker. Up to 10 different amplitudes can be stored for quick recall when setting the amplitude of the shock stimulus manually. Maximum Output Current: 5 milliamps into 50 KOhms Current Resolution: 1.25 microamps Maximum Output Voltage: 300 volts Maximum Subject Resistance: = (300/desired current) 10 KOhms Output Waveform: Square pulse Pole Select: 2 or 8 Dimensions: 10-inches Wide x 7-inches Deep x 3.25-inches High.

This devices is available in two versions:
  • H13-17A -> PROGRAMMABLE ANIMAL SHOCKER 110V
  • H13-17A-220 -> PROGRAMMABLE ANIMAL SHOCKER 220V
25FT SHOCK CABLE - 8 CONDUCTOR
25FT SHOCK CABLE - 8 CONDUCTOR
Contact our Behavioral Research Specialists for more information

A 25 foot (7.62 m) / 50 foot (15.24 m), 8-conductor ribbon cable with a connector on one end for connection to the output of the shocker and a connector on the other end for the grid floors of the operant test cage, the shock transfer board on shuttle cages, or the H93-30 Shock Distributor Board for runways and hubs.
50FT SHOCK CABLE - 8 CONDUCTOR
50FT SHOCK CABLE - 8 CONDUCTOR
Contact our Behavioral Research Specialists for more information

A 25 foot (7.62 m) / 50 foot (15.24 m), 8-conductor ribbon cable with a connector on one end for connection to the output of the shocker and a connector on the other end for the grid floors of the operant test cage, the shock transfer board on shuttle cages, or the H93-30 Shock Distributor Board for runways and hubs.
32IN JUMPER CABLE - 8-CONDUCTOR
32IN JUMPER CABLE - 8-CONDUCTOR
Contact our Behavioral Research Specialists for more information

This 32in 8-Conductor Jumper passes through the cubicle to the grid floor when a cage is used in a cubicle. It is also used to connect the hub/runway distributor board (H93-30) to test-cage type grid connector (same connector as H93-01-25 and H93-01-50).
25FT SHOCK CABLE - 2-POLE/UNIVERSAL CLIPS
25FT SHOCK CABLE - 2-POLE/UNIVERSAL CLIPS
Contact our Behavioral Research Specialists for more information

A 25-foot (7.62 m) / 50 foot (15.24 m), 2-conductor cable with an 8-pin connector on one end for connection to the output of the H13-15 or H13-16 shockers when used in the two pole mode.  The other end of the cable has universal clips to connect to a variety of attached cutaneous electrodes, lickometers, or other devices used for aversive stimulation.
50FT SHOCK CABLE - 2-POLE/UNIVERSAL CLIPS
50FT SHOCK CABLE - 2-POLE/UNIVERSAL CLIPS
Contact our Behavioral Research Specialists for more information

A 25-foot (7.62 m) / 50 foot (15.24 m), 2-conductor cable with an 8-pin connector on one end for connection to the output of the H13-15 or H13-16 shockers when used in the two pole mode.  The other end of the cable has universal clips to connect to a variety of attached cutaneous electrodes, lickometers, or other devices used for aversive stimulation.
SHOCK FLOOR SHORTING PLUG
SHOCK FLOOR SHORTING PLUG
Contact our Behavioral Research Specialists for more information

The H93-25 is used for 2-Pole shock applications when the shock gird floor is used.  The shorting plug ties all of the grids together as a single pole so that one pole of the shock output is the grid floor.  Commonly used in applications like the Vogel procedure or any application where the shock source is being delivered between the grid floor and another conductive object.
SHOCK DISTRIBUTOR BOARD FOR HUBS/RUNWAYS
SHOCK DISTRIBUTOR BOARD FOR HUBS/RUNWAYS
Contact our Behavioral Research Specialists for more information

This Shock Distributor board is used for distributing shock from the H13-15 or H13-16 shockers to hubs and runways.  It accepts H93-01-25 and H93-01-50 cables from the shockers and distributes the shock to runways and hubs via the H93-31-32 or to the test and shuttle cages via another H93-01-25 or H93-01-50 shock cable for parallel connections of all arena and runway elements in a single-subject environment.