|
|
|
|
 |
EXTENDED PELLET DELIVERY TROUGH - MOUSE
|
Contact our Behavioral Research Specialists for more information
|
|
|

The Extended Mouse Pellet Trough is used when implanted electrodes prevent the use of the standard H14-01M Mouse Pellet Trough. A cup extends into the cage so the subject does not have to place their head into an opening.
|
|
 |
|
|
|
|
 |
LIQUID DELIVERY RESERVOIR - MOUSE
|
Contact our Behavioral Research Specialists for more information
|
|
|

This is the same reservoir used in the H14-04M Mouse Liquid Solenoid Valve. It is fitted with needle tubing on the rear to receive a catheter-sized tube when the amount of liquid is being controlled by an infusion pump. Used when precise small volumes or precision amounts of liquid are being used. Can also be used when the subject has implanted electrodes preventing them from entering the opening on a Liquid Dipper.
|
|
 |
|
|
|
|
 |
LIQUID DELIVERY RESERVOIR - RAT
|
Contact our Behavioral Research Specialists for more information
|
|
|

This is the same reservoir used in the H14-04R Rat Liquid Solenoid Valve. It is fitted with needle tubing on the rear to receive a catheter-sized tube when the amount of liquid is being controlled by an infusion pump. Used when precise small volumes or precision amounts of liquid are being used. Can also be used when the subject has implanted electrodes preventing them from entering the opening on a Liquid Dipper.
|
|
 |
|
|
|
|
 |
LIQUID SOLENOID VALVE - MOUSE
|
Contact our Behavioral Research Specialists for more information
|
|
|

The solenoid calve is designed to dispense non-viscous fluids. It should be used for water, drugs in water solution, but not heavy suspensions or solutions that leave a sticky residue such as sugar. The quantity delivered is controlled by means of a combination of the supply bottle height, valve adjustment and the duration of actuation. The delivery cup reservoir will hold fluid until consumed by the animal. A 1-liter supply bottle with a compatible fitting is supplied with the unit.
|
|
 |
|
|
|
|
 |
LIQUID SOLENOID VALVE - RAT
|
Contact our Behavioral Research Specialists for more information
|
|
|

The solenoid calve is designed to dispense non-viscous fluids. It should be used for water, drugs in water solution, but not heavy suspensions or solutions that leave a sticky residue such as sugar. The quantity delivered is controlled by means of a combination of the supply bottle height, valve adjustment and the duration of actuation. The delivery cup reservoir will hold fluid until consumed by the animal. A 1-liter supply bottle with a compatible fitting is supplied with the unit.
|
|
 |
|
|
|
|
 |
REPLACEMENT LIQUID RESERVIOR (FOR H14-05, -05M AN D-06)
|
Contact our Behavioral Research Specialists for more information
|
|
|

Replacement reservoir for the H14-05M-LED and H14-05R-LED Liquid Dippers.
|
|
 |
|
|
|
|
 |
EXTENDED LIQUID DIPPER - RAT
|
Contact our Behavioral Research Specialists for more information
|
|
|

The Extended Liquid Dipper is used when implanted electrodes prevent the use of the standard H14-05R-LED Rat Liquid Dipper. A cup extends into the cage so the subject does not have to place their head into an opening.
|
|
 |
|
|
|
|
 |
LIQUID DIPPER CUP 0.02CC (FOR H14-05, -05M AND -06)
|
Contact our Behavioral Research Specialists for more information
|
|
|

The dipper arm used in the H14-05M-LED, -05R-LED, and H14-06R-LED dippers is finished with a 0.01 cc volume cup machined directly into the end of the arm. For larger volumes, interchangeable cups may be ordered and attached to the end of the arm. They slip over the the end of the arm and are held in place by a small, recessed set screw. The cup and screw are stainless steel. An allen wrench is provided with the cups.
Order by volume using the following numbers: H14-06-CP-02 for 0.02 cc H14-06-CP-04 for 0.04 cc H14-06-CP-06 for 0.06 cc H14-06-CPS-03 for a set that contains all three volumes above
|
|
 |
|
|
|
|
 |
LIQUID DIPPER CUP 0.04CC (FOR H14-05, -05M AND -06)
|
Contact our Behavioral Research Specialists for more information
|
|
|

The dipper arm used in the H14-05M-LED, -05R-LED, and H14-06R-LED dippers is finished with a 0.01 cc volume cup machined directly into the end of the arm. For larger volumes, interchangeable cups may be ordered and attached to the end of the arm. They slip over the the end of the arm and are held in place by a small, recessed set screw. The cup and screw are stainless steel. An allen wrench is provided with the cups.
Order by volume using the following numbers: H14-06-CP-02 for 0.02 cc H14-06-CP-04 for 0.04 cc H14-06-CP-06 for 0.06 cc H14-06-CPS-03 for a set that contains all three volumes above
|
|
 |
|
|
|
|
 |
LIQUID DIPPER CUP 0.06CC (FOR H14-05, -05M AND -06)
|
Contact our Behavioral Research Specialists for more information
|
|
|

The dipper arm used in the H14-05M-LED, -05R-LED, and H14-06R-LED dippers is finished with a 0.01 cc volume cup machined directly into the end of the arm. For larger volumes, interchangeable cups may be ordered and attached to the end of the arm. They slip over the the end of the arm and are held in place by a small, recessed set screw. The cup and screw are stainless steel. An allen wrench is provided with the cups.
Order by volume using the following numbers: H14-06-CP-02 for 0.02 cc H14-06-CP-04 for 0.04 cc H14-06-CP-06 for 0.06 cc H14-06-CPS-03 for a set that contains all three volumes above
|
|
 |